Unable to recognize the server from a managing PC:
Did you configure [Initialize Remote Management Card]?
→ Start the server-accessory NEC EXPRESSBUILDER, then go to [Tools] -
[Initialize Remote Management Card] to write each server information in order
to initialize the card.
Does your management PC contain Java2 RuntimeEnvironment, Standard Edition
1.4.2_04 or later?
→Java2 RuntimeEnvironment, Standard Edition 1.4.2_04 or later is required. Use
the following procedure to install.
Start Windows on a management PC that you want to install the Java, then
insert the NEC EXPRESSBUILDER DVD into the DVD-ROM drive. Windows
automatically launches the Autorun menu.
Click [Software Setup] - [DianaScope]. Run the JRE installer in the
DianaScope installation menu.
# If you would like to install the latest Java Runtime, go to the following
website to download:
However, as JRE6 and later are not supported, they cannot be used.
Do you connect LAN cable appropriately?
→Check if LAN cable is connected appropriately. The server sensors work
Check if IP address is duplicated?
→IP address for the management LAN port is configured as 192.168.1.1 at the
Did you set NEC ESMPRO Agent to monitor the server?
→Modify the environment setting file of snmpd (/etc/snmp/snmpd.conf) to set
Is network connection restricted by the firewall or thegateway?
→Network connection may be restricted by a firewall setting. See if you can
http://java.sun.com/j2se/
properly only when the cable is connected properly. Make sure the cable isn't
mistakenly connected to the server's LAN connector or to the serial port
connector.
factory default setting. Change the IP address if this one is already used on the
network, as this one isn't recognized appropriately.
a community privilege to "READ WRITE". In addition, please confirm
whether community name setting agrees with the community name which it
set in SNMP environment preference on NEC ESMPRO Agent.
The community name setting in ESMPRO/ServerAgent starts Control Panel
(/opt/nec/esmpro_sa/bin/ESMagntconf), and please confirm [SNMP
Community] of the [General Properties].
solve the problem by connecting the server and a client PC directly with a
cross cable. Refer to Chapter 4 [Remote Management Function] - [BMC
Configuration] - [Network Configuration], then check the port of the Remote
Management Card and set the firewall or the gateway.
Troubleshooting 7-17