Impact When Module Status Changes
PCI modules, SCSI adapters, SCSI buses, and modules under the SCSI enclosure have impact on
each other. For example, when the "Status" item of a module changes to "fault," it may be caused
by another module's error. Therefore, you need to check the status of the other modules based on
alert information.
LAN Monitoring Report
The LAN monitoring function defines the line status depending on the number of transmission
packets and the number of packet errors within a certain period. Thus, the LAN monitoring function
may report a line fault or high line load only in a temporary high line impedance state. If a normal
state recovery is reported immediately, temporal high line impedance may have occurred thus there
is not any problem.
Setting of Data viewer at update intervals
Set the update interval of Data Viewer 60 seconds(default) or more.
Otherwise, a report might be delayed or not be sent.