NEC N8800-162F User Manual page 74

Express5800/ft series
Table of Contents

Advertisement

3-6 Linux Setup and Operation
4 Repair Mirroring Arrays
5 Delete Mirroring Arrays
6 Remove Disk Partitions
7 Make Striping Array
8 Delete Striping Array
c Configurations
q Quit
Command: 1 (Check if the disk specified is isolated from the RAID
configuration.)
[List RAID Arrays]
Name
Partition
=======================================================
< Mirroring Array (RAID1)>
md0
/boot
md1
swap
md2
/
md3
/var/crash
(After verifying the isolation of the specified disk from the
RAID configuration (verifying no partition of the specified disk
is in Member), replace the hard disk. Wait approximately five
minute before the system starts to resynchronize. If there is
no automatic synchronization, manually restore the disk with the
below procedure.)
Command action
1 List RAID Arrays
2 List Internal Disks
3 Make Mirroring Arrays
4 Repair Mirroring Arrays
5 Delete Mirroring Arrays
6 Remove Disk Partitions
7 Make Striping Array
8 Delete Striping Array
c Configurations
q Quit
Command: 2
system.)
[List Internal Disks]
Slot
Name [use]
============================================================
1
sda (sdq)
2
-
3
-
4
-
5
-
6
-
7
-
8
-
9
sdi (sdr)
10
-
11
-
(Label)
( - )
( - )
( - )
( - )
(Check if the replaced disk is recognized by the
Informati
on
[4]
[4]
(RAID1)
(RAID1)
(RAID1)
(RAID1+0)
(RAID1+0)
Status
Member
SIMPLEX
(1)sda1
SIMPLEX
(1)sda2
SIMPLEX
(1)sda3
SIMPLEX
(1)sda5
(RAID1)
(RAID1)
(RAID1)
(RAID1)
(RAID1+0)
(RAID1+0)
(Vendor/Model/Serial)
AAA/BBB/#CCC
AAA/BBB/#CCC
path
h5c0t12810
h6c0t12810

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

N8800-163fExp320lExp320mNec express5800 series

Table of Contents