On-screen error message
0252 Password checksum
bad -Password cleared
0260 System Timer error
0270 Real time clock error
0271 Check date and time
setting
02D0 System cache error –
Cache disabled
02D1 System Memory
exceeds the CPU's
caching limit
02F0 CPU ID
0613 COM A configuration
change
0614 COM A config, error –
device disable
0615 COM B configuration
change
0616 COM B config, error –
device disable
0B28 Unsupported Processor
detected on Processor 1
0B29 Unsupported Processor
detected on Processor 2
0B80 BMC Memory Test
Failed
0B81 BMC Firmware Code
Area CRC check failed
0B82 BMC core Hardware
failure
0B83 BMC IBF or OBF check
Failed
0B8B BMC progress check
timeout
0B8C BMC command access
failed
0B90 BMC Platform
Information Area
corrupted
0B91 BMC update firmware
corrupted
0B92 Internal Use Area of
BMC FRU corrupted
0B93 BMC SDR Repository
empty
0B94 IPMB signal lines do not
respond
0B95 BMC FRU device failure
Cause
Password is cleared.
System Timer is faulty.
RTC is faulty.
Date and time are incorrectly
set.
CPU cache is faulty.
CPU cache is faulty.
CPU is faulty
COM A configuration is
faulty.
Device constructing COM A
is faulty.
COM B configuration is
faulty.
Device constructing COM A
is faulty.
Unsupported CPU is
mounted.
Unsupported CPU is
mounted.
RMC device is faulty.
RMC device is faulty.
BMC check is suspended.
BMC command access
failed.
BMC device is faulty.
Data within SROM is faulty.
SDR data is faulty.
SMC is faulty.
NVRAM within BMC is faulty.
Troubleshooting 7-5
Action
Reconfigure by using BIOS setup.
Reconfigure by using BIOS setup.
If the error cannot be solved after
this, replace the CPU/IO module.
If replacing the CPU does not
help, replace the CPU/IO module.
If restarting does not help after
resetting the setting to default by
using BIOS setup, replace the
CPU/IO module.
Check the supported CPU and
replace it. If this does not help,
replace the CPU/IO module.
Replace the CPU/IO module.
Replace the CPU/IO module.
Replace the CPU/IO module.
Replace the CPU/IO module.
Replace the CPU/IO module.
Replace the system backboard.
If updating SDR does not help,
replace the CPU/IO module.
Replace the CPU/IO module or a
system backboard after
determining where IPMB error
has occurred based on OS
information.
Replace the CPU/IO module.