3-4 Setting Up Your Server

SELECTING SERVER SITE

Read the following precautions before selecting a suitable site for your server. The following
describes installation of the server and connections to the server.
The following figure illustrates a site suitable for installing the server.
Install the server on the
floor or rigid, flat desk.
Place having a space enough to fully
open the front door (The front door
extrudes about 35 mm from the left
side of the server when fully opened.)
Observe the following instructions to use the server safely. Failure to follow
these instructions may cause a fire, personal injury, or property damage. See
pages 1-3 to 1-8 for details.
Never attempt to lift the server only by yourself.
Do not install the server in any place other than specified.
Room that satisfies the following conditions: *
Temperature:
Humidity:
Temperature gradient: ±10ºC/h
Atmosphere (hpa):
Open the stabilizers
to secure the server.
CAUTION
<While operating> <While halting>
10 to 35ºC
5 to 40ºC
20 to 80%
10 to 80%
±15ºC/h
749 to 1040
749 to 1040 hpa
Close enough to connect
the mouse and the display.
Allow clearance of at
least 150 mm in front of
and rear of the server.
* It is recommended that the
server should be used in a
room where temperature is in
the range between 15 to 25ºC.
100 to 120 Vac/200 to
240 Vac parallel bi-
polar wall power outlet
with the ground line.
Wall outlet to
connect the
supplied power
cord.
UPS to prevent momentary
voltage drop due to power
failure or lightning *
* Optional. UPS is
recommended for best
use of features of server.