Undo R & B Convergence Mid; Commont Settings - Barco R9002411 Owner's Manual

Table of Contents

Advertisement

Undo R & B Convergence Mid
When "R & B convergence mid" is selected, all convergence
settings are set to their midposition. With the undo, it is
possible to return to the previous settings as long as the
projector is playing on the same source (= same adjustment
block).
'Undo R & B convergence mid' is displayed in the Memory
management menu instead of 'R & B convergence mid' when
this latter is pressed.
Push the cursor key é or ê to highlight 'Undo R & B
convergence mid'.
'
Press ENTER execute the undo function.
Again a confirmation screen will be displayed first.
Press ENTER to confirm.
Press EXIT to cancel the procedure.
Common Settings
Highlight 'Common settings' by pushing the control arrow up or down and press ENTER
to display the common settings menu.
Within the common settings menu, the following items can be set up or executed :
- G2 adjustment
- CRT run in cycle
G2 Adjustment
Item is password protected.
Highlight 'G2 adjust' with the control arrow and press ENTER to continue.
A safety notice will be displayed on the screen as it is necessary to open the top cover
to adjust the G2.
ENTER selects the G2 adjustment.
EXIT returns to the Common settings menu.
ADJUST returns to the Operational mode.
'G2 adjustment should be performed by BARCO personnel, or BARCO authorized
dealers'.
If you are qualified, press ENTER to continue. if not qualified, press EXIT to return to the
Commmon settings menu. Further description of the G2 adjustment is given in the
installation manual.
R5976101.02 BARCO CINE5 310102 ___________________________________________________________________________
MEMORY MANAGEMENT
COPY A BLOCK
DELETE A BLOCK
DELETE ALL BLOCKS
ALL SETTINGS TO MIDPOS
UNDO R & B CONVERGENCE TO MID
or
Select with
then <ENTER>
<EXIT> to return
Service Mode
CONVERGENCE OFF
convergence setting
in current block
will be overwritten !
<ENTER> to Confirm
<EXIT> to cancel
SERVICE MODE
PROJECTOR SET-UP
MEMORY MANAGEMENT
COMMON SETTINGS
I2C DIAGNOSTICS
or
Select with
then <ENTER>
<EXIT> to return
COMMON SETTINGS
G2 ADJUSTMENT
CRT RUN IN CYCLE
or
Select with
then <ENTER>
<EXIT> to return
COMMON SETTINGS
G2 ADJUSTMENT
CRT RUN IN CYCLE
or
Select with
then <ENTER>
<EXIT> to return
SAFETY
NOTICE
RISK OF ELECTRICSAL SHOCK
G2 ADJUSTMENT SHOULD BE
PERFORMED BY BARCO
PERSONNEL, OR BARCO
AUTHORIZED DEALERS.
IF QUALIFIED, PRESS
<ENTER> TO CONTINUE OR
IF NOT, <EXIT> TO RETURN
7-7