Temperature Sensor Thresholds

The projector shutdowns within one minute of an error threshold being reached.
Location
Integrator Rod
Prism
Air Intake
Lamp Exhaust
MCPU
ABP
HIP Scaler
HIP Warp Red
HIP Warp Green
HIP Warp Blue
Formatter Red
DMD Red
Formatter Green
DMD Green
Formatter Blue
DMD Blue
Option Card 1
Option Card 2
Option Card 3
Option Card 4
EVB
Lens MCB
Lamp MCB
D4K2560/Mirage 4K25 User Manual
020-101076-02 Rev. 1 (11-2013)
Warning
Error
(°C)
(°C)
110
120
60
70
44
49
85
N/A
70
95
82
95
82
95
82
95
82
95
82
95
82
95
63
68
82
95
63
68
82
95
63
68
80
95
80
95
80
95
80
95
70
95
75
95
v1.0x software only; removed in v1.1.0+ software
70
95
v1.0x software only; removed in v1.1.0+ software
Remarks
Specification