Specification
Warning Thresholds for Fans
The following thresholds are implemented for v1.1.0 software and above.
All fan warnings are set to ~75% of their normal operating speeds.
Location
Light Engine Intake (Fan 5)
Light Engine Intake (Fan 6)
Light Engine Intake (Fan 8)
Formatter—Green Blower (Fan 7)
Laminar Airflow Device (Fan 4)
Electronics Intake (Fan 10)
Electronics Intake (Fan 11)
Electronics Intake (Fan 12)
Image Processor Warp Blower (Fan 9)
Electronics Exhaust (Fan 1)
Electronics Exhaust (Fan 2)
Liquid Cooling Radiator (Fan 3)
Image Processor Scaler (Fan 13)
Warning Threshold for Liquid Cooling Module
Location
Flow Meter
Liquid Cooling Pump
Touch Panel Controller (TPC)
Type of Display
Display Size
Display Resolution (H x V pixels)
Maximum Dimensions (W x H x D)
Integrated Operating System
Communication Interface with Projector
60
Warning
RPM
3300
3300
3300
3500
5900
5700
5700
5700
2400
3400
3400
1800
5100
Warning
0.2mL/min
180RPM
TPC 650H
Color VGA TFT LCD, backlit
144.8 mm (5.7 inches) diagonal
640 x 480
195 mm x 148 mm x 58 mm
Microsoft Windows® XPe
10/100/1000 BaseT Ethernet
D4K2560/Mirage 4K25 User Manual
020-101076-02 Rev. 1 (11-2013)