7.
The bearings can now be slid off the shaft. Inspect the bearings for
excess play or roughness. Replace the bearings, if necessary. Install
the shaft in the reverse order of the removal procedures.
8.
Adjust the alternator Poly-V and HTD belts (see the "Alternator Poly-V
Belt" and "HTD Belt" sections for tensioning instructions). Adjust the
HTD belt first, then the alternator Poly-V belt.
9.
Reattach the side covers.

MAIN CABLE

1.
Remove the left side cover, the outside weight stack cover, and the
console.
2.
Note and mark (by color) the location of each wire attached to the
alternator (see Wiring Diagram 1).
3.
Detach the wires from the alternator. Disconnect the power connector.
4.
Disconnect the main cable from the console.
5.
Remove the main cable from the wire saddles (see Figure 30).
6.
Tie a length of string about five feet long to the console connection of
the old cable and to the lower end of the new main cable.
7.
Pull the old cable out of the frame arch and feed the new cable
through the upper hole in the frame. Be careful to retain the rubber
grommets.
8.
When the wire ends of the new cable reach the lower hole, untie the
string and pull the cable through. Be sure to seat the rubber grom-
mets into the holes in the frame to prevent damage to the cable.
9.
Insert the main cable into the wire saddles.