Connecting The Realpresence Collaboration Server (Rmx) 1500 To Ac Power; Connecting Cables To The Realpresence Collaboration Server (Rmx) 1500 - Polycom 1500 Hardware Manual

Realpresence collaboration server (rmx) 1500
Hide thumbs Also See for 1500:
Table of Contents

Advertisement

RealPresence Collaboration Server (RMX) 1500 Hardware Guide
● Listed fastening hardware must be compatible with the materials being joined and must be preclude
loosening, deterioration and electrochemical corrosion of the hardware and joint materials.

Connecting the RealPresence Collaboration Server (RMX) 1500 to AC Power

Do not connect the green or green-yellow wire to the system single-point ground screw.
Only the AC Power cable supplied by Polycom should be used.
The size of the protective earthing conductor should be a minimum of 10AWG.
The outlet intended for connecting the power cord must be protected with an external overcurrent
protection device either in building or in the rack with the rating not higher than 20Amp.
Do not use an extension cord with the cable.
To connect the RealPresence Collaboration Server (RMX) 1500 to AC Power:
1 Make sure that the power (push) button is switched OFF on the Collaboration Server (RMX) 1500.
2 Insert the power cable into the Power Connector on the rear panel of the Collaboration Server
(RMX) 1500.
Connecting Cables to the RealPresence Collaboration Server (RMX)
1500
Connect the cables to the RMX 1500 in the order given below.
To connect the cables:
● For the RTM-IP 1500 module:
 Connect the Media cable to LAN 2 port. This port is used for Media Redundancy or for Multiple
Network Configuration. For more information, see RealPresence® Collaboration Server (RMX)
1500/1800/2000/4000 Administrator's Guide,
 Connect the LAN network cable to the MNGB (Management Network) port. This port is used for
Signaling Redundancy or for Multiple Network Configuration.
 Optional. Connect the LAN signaling cable to the MNG (Signaling) port. This port is used for
Signaling and Management Redundancy. For more information, see RealPresence®
Collaboration Server (RMX) 1500/1800/2000/4000 Administrator's Guide,
Multiple Network Services
 Optional. Connect the Shelf Management cable to the Shelf port.
Polycom, Inc.
LAN Redundancy
.
Multiple Network Services
and
LAN Redundancy
.
and
21