Loop Protection; Configuration - Planet IGS-10020MT User Manual

Industrial 8-port 10/100/1000t + 2 100/1000x sfp managed switch
Hide thumbs Also See for IGS-10020MT:
Table of Contents

Advertisement

4.16 Loop Protection

This page allows the user to inspect the current Loop Protection configurations, and possibly change them as well.

4.16.1 Configuration

This page allows the user to inspect the current Loop Protection configurations,
The page includes the following fields:
General Settings:
Object
Enable Loop
Protection
Transmission Time
 Shutdown Time
Figure 4-16-1: Loop Protection Configuration Page Screenshot
Description
Controls whether loop protections is enabled (as a whole).
The interval between each loop protection PDU sent on each port. valid values
are 1 to 10 seconds.
The period (in seconds) for which a port will be kept disabled in the event of a
loop is detected (and the port action shuts down the port). Valid values are 0 to
604800 seconds (7 days). A value of zero will keep a port disabled (until next
device restart).