4.3.2 Starting interrupt program from QCPU to C Controller module/PC CPU
module
Using the multiple CPU transmission dedicated instruction in Table4.17, an interrupt program can be started from the
QCPU to the C Controller module/PC CPU module.
The interrupt program from the PC CPU module to other CPU module cannot be started.
An interrupt program can be started from the C Controller module to the Motion CPU or the C Controller module in
another CPU.
For details, refer to the manual of the C Controller module.
Instruction name
S.GINT
SP.GINT
(Example) When using the S.GINT instruction
The interrupt program from the QCPU to the PC CPU module can be started.
Remark
For details and availability of the multiple CPU transmission dedicated instruction, refer to the manuals of the C Controller
module and PC CPU module.
4 - 51
Table4.17 CPU transmission dedicated instraction
Requests start up of other CPU's interrupt programs.
QCPU
Start request
S.GINT instruction
Figure 4.47 Operation of S.GINT instruction
Description
PC CPU module
Interruption program