System Fails To Boot; Drives "Dead" At System Boot; Added Drive Defective - Fujitsu PRIMERGY RX600 S3 Operating Manual

Hide thumbs Also See for PRIMERGY RX600 S3:
Table of Contents

Advertisement

System Fails to Boot

7.7
System Fails to Boot
The system fails to boot after installing a new hard disk drive.
SCSI configuration incorrect
Ê Check the settings for the hard disk drives in the SCSI configuration menu.
7.8

Drives "dead" at System Boot

RAID controller configuration incorrect
Ê Check and correct the settings for the drives with the RAID controller utility.
Further information is provided in the manual on the RAID controller.
7.9

Added Drive Defective

RAID controller is not configured for this hard disk drive
The drive was installed with the system switched OFF.
Ê Reconfigure the RAID controller for the drive with the corresponding utility.
Information is contained in the documentation on the RAID controller.
or
Ê Re-insert the HDD module with the system switched ON into a free module
bay.
If the hard disk drive continues to be shown as defective, then replace it (see
section "Installing/Removing a HDD/Dummy Module" on page
72
Problem Solutions and Tips
80).