IGNITION SYSTEM
2. Inspect:
Charging coil 1 resistance
Out of specification
Tester (+) lead
Tester (–) lead
5PA60090
3. Inspect:
Charging coil 2 resistance
Out of specification
Tester (+) lead
Tester (–) lead
5PA60100
EC628000
CDI UNIT INSPECTION
Check all electrical components. If no fault is
found, replace the CDI unit. Then check the
electrical components again.
6 - 5
ELEC
Replace.
Black/Red lead 1
Green/White lead 2
Charging coil 1
Tester selector
resistance
720 ~ 1,080
at 20 °C (68 °F)
Replace.
Green/Blue lead 1
Black lead 2
Charging coil 2
Tester selector
resistance
44 ~ 66
at
20 °C (68 °F)
–
+
position
100
position
10