Brocade Communications Systems Brocade 8/12c Reference page 63

Brocade fabric os mib reference supporting fabric os v7.0.0 (53-1002151-01, april 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

Object and OID
ipAddressTable
1.3.6.1.2.1.4.34
ipAddressEntry
1.3.6.1.2.1.4.34.1
ipAddressAddrType
1.3.6.1.2.1.4.34.1.1
ipAddressAddr
1.3.6.1.2.1.4.34.1.2
ipAddressIfIndex
1.3.6.1.2.1.4.34.1.3
ipAddressType
1.3.6.1.2.1.4.34.1.4
ipAddressPrefix
1.3.6.1.2.1.4.34.1.5
ipAddressOrigin
1.3.6.1.2.1.4.34.1.6
ipAddressStatus
1.3.6.1.2.1.4.34.1.7
ipAddressCreated
1.3.6.1.2.1.4.34.1.8
ipAddressLastChange
d
1.3.6.1.2.1.4.34.1.9
ipAddressRowStatus
1.3.6.1.2.1.4.34.1.10
ipAddressStorageType
1.3.6.1.2.1.4.34.1.11
Fabric OS MIB Reference
53-1002151-01
Access
Description
Not
This table contains IPv4 and IPv6 addressing information relevant to the
accessible
entity's interfaces.
Not
An address mapping for a particular interface.
accessible
Not
The address type of ipAddressAddr.
accessible
Not
The IP address to which this entry's addressing information pertains.
accessible
Read
The index value that uniquely identifies the interface to which this entry is
create
applicable. The interface identified by a particular value of this index is the
same interface as identified by the same value of the ifIndex of IF MIB.
Read
The type of address.
create
Valid values:
unicast (1)
anycast (2)
broadcast (3) - This is not a valid value for IPv6 addresses.
Read only
A pointer to the row in the prefix table to which this address belongs. May
be {0 0} if there is no such row.
Read only
The origin of the address.
Read
The status of the address, describing if the address can be used for
create
communication.
Valid values:
preferred (1)
deprecated (2)
tentative (3)
In the absence of other information, for an IPv4 address, the status is
always preferred (1).
Read only
The value of sysUpTime at the time this entry was created. If this entry was
created prior to the last re-initialization of the local network management
subsystem, then this object contains a zero value.
Read only
The value of sysUpTime at the time this entry was last updated. If this entry
was updated prior to the last re-initialization of the local network
management subsystem, then this object contains a zero value.
Read
The status of this conceptual row.
create
Read
The storage type for this conceptual row. If this object has a value of
create
'permanent', then no other objects are required to be able to be modified.
2
IP group
43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.0.0

Table of Contents