Brocade Communications Systems Brocade 8/12c Reference page 129

Brocade fabric os mib reference supporting fabric os v7.0.0 (53-1002151-01, april 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

Object and OID
entPhysicalClass
1.3.6.1.2.1.47.1.1.1.1.5
(continued)
entPhysicalParentRelPos
1.3.6.1.2.1.47.1.1.1.1.6
Fabric OS MIB Reference
53-1002151-01
Access
Description
Read only
Brocade 7800 Extension switch can have the following hierarchy of
physical objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (one switch blade, two
power supplies, two fans)
Module: One entry for switch blade, up to two entries for power
supplies, and up to two entries for fans
Brocade 6510 switch can have the following hierarchy of physical
objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (one switch blade, two
power supplies, two fans)
Module: One entry for switch blade, up to two entries for power
supplies, and up to two entries for fans
Brocade DCX 8510-4 Backbone can have the following hierarchy of
physical objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (four port blades, two CPs,
two power supplies, two fans)
Module: Eight entries for port blades, two entries for CPs, four
entries for power supplies, and three entries for fans
Brocade DCX 8510-8 Backbone can have the following hierarchy of
physical objects:
Chassis: One entry (one row)
Container: One entry for each FRU slot (eight port blades, two CPs,
four power supplies, three fans)
Module: Eight entries for port blades, two entries for CPs, four
entries for power supplies, and three entries for fans
Read only
An indication of the relative position of this child component among all
its sibling components. Sibling components are defined as
entPhysicalEntries that share the same instance values of each of the
entPhysicalContainedIn and entPhysicalClass objects.
For chassis entry, this value is -1; for containers, it is the sequential
number of the container from the first one; for all FRUs, it is always 1.
An NMS can use this object to identify the relative ordering for all
sibling components of a particular parent (identified by the
entPhysicalContainedIn instance in each sibling entry).
This value should match any external labeling of the physical
component if possible. For example, for a container (such as a card
slot) labeled slot #3, entPhysicalParentRelPos should have the value 3.
Note that the entPhysicalEntry for the module plugged into slot 3
should have an entPhysicalParentRelPos value of 1.
If the physical position of this component does not match any external
numbering or clearly visible ordering, then user documentation or other
external reference material should be used to determine the
parent-relative position. If this is not possible, then the agent should
assign a consistent (but possibly arbitrary) ordering to a given set of
sibling components, perhaps based on internal representation of the
components.
Physical entity group