Object and OID
swNsNodeSymb
1.3.6.1.4.1.1588.2.1.1.1.7.2.1.7
swNsIPA
1.3.6.1.4.1.1588.2.1.1.1.7.2.1.8
swNsIpAddress
1.3.6.1.4.1.1588.2.1.1.1.7.2.1.9
swNsCos
1.3.6.1.4.1.1588.2.1.1.1.7.2.1.10
swNsFc4
1.3.6.1.4.1.1588.2.1.1.1.7.2.1.11
swNsIpNxPort
1.3.6.1.4.1.1588.2.1.1.1.7.2.1.1
2
swNsWwn
1.3.6.1.4.1.1588.2.1.1.1.7.2.1.1
3
swNsHardAddr
1.3.6.1.4.1.1588.2.1.1.1.7.2.1.14
Fabric OS MIB Reference
53-1002151-01
Access
Description
Read only
The contents of a Symbolic Name of the node associated with
the entry. In FC-GS-2, a Symbolic Name consists of a byte array
of 1 through 256 bytes, and the first byte of the array specifies
the length of its contents. This object variable corresponds to
the contents of the Symbolic Name, with the first byte removed.
Read only
The Initial Process Associators of the node for the entry as
defined in FC-GS-2. This value is read only and cannot be
changed.
Read only
The IP address of the node for the entry as defined in FC-GS-2.
The format of the address is in IPv6.
Read only
The class of services supported by the port. This value is a
hard-coded bitmap and indicates the supported services as
follows:
•
Class F (1)
•
Class 1 (2)
•
Class F-1 (3)
•
Class 2 (4)
•
Class F-2 (5)
•
Class 1-2 (6)
•
Class F-1-2 (7)
•
Class 3 (8)
•
Class F-3 (9)
•
Class 1-3 (10)
•
Class F-1-3 (11)
•
Class 2-3 (12)
•
Class F-2-3 (13)
•
Class 1-2-3 (14)
•
Class F-1-2-3 (15)
Read only
The FC-4s supported by the port, as defined in FC-GS-2.
Read only
The object identifies IpAddress of the Nx_Port for the entry.
Read only
The object identifies the World Wide Name (WWN) of the
Fx_Port for the entry.
Read only
The object identifies the 24-bit hard address of the node for the
entry.
Name Server database group
6
155