Brocade Communications Systems Brocade 8/12c Reference page 179

Brocade fabric os mib reference supporting fabric os v7.0.0 (53-1002151-01, april 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

Object and OID
swFwThLevel
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.1
3
swFwWriteActVals
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.1
4
swFwDefaultChangedActs
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.1
5
swFwDefaultExceededActs
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.1
6
swFwDefaultBelowActs
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.1
7
swFwDefaultAboveActs
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.1
8
swFwDefaultInBetweenActs
1.3.6.1.4.1.1588.2.1.1.1.10.2.1.1
9
Fabric OS MIB Reference
53-1002151-01
Access
Description
Read-write This object is used to point to the current level for classArea
values. It is either default or custom.
For a read operation, the return value is either 2 (swFwDefault)
or 3 (swFwCustom). 1 (swFwReserved) is obsolete.
If the write operation sets the variable to 2 (swFwDefault), the
following default configuration variables are used for the Fabric
Watch classArea combination:
swFwDefaultUnit
swFwDefaultTimebase
swFwDefaultLow
swFwDefaultHigh
swFwDefaultBufSize
If the write operation sets the variable to 3 (swFwCustom), the
following custom configuration variables are used for the Fabric
Watch classArea combination:
swFwCustUnit
swFwCustTimebase
swFwCustLow
swFwCustHigh
swFwCustBufSize
Read-write This applies or cancels the alarm value changes.
For a read operation, the return value is always
swFwCancelWrite.
The following are the custom alarm variables that can be
modified:
swFwCustChangedActs
swFwCustExceededActs
swFwCustBelowActs
swFwCustAboveActs
swFwCustInBetweenActs
Changes to these custom alarm variables can be saved by
setting this variable to swFwApplyWrite.
Changes to these custom alarm variables can be removed by
setting this variable to swFwCancelWrite.
Read only
Default action matrix for changed event.
Read only
Default action matrix for an exceeded event. The exceeded value
might be either above the high threshold or below the low
threshold.
Read only
Default action matrix for below event.
Read only
Default action matrix for above event.
Read only
Default action matrix for in-between event.
Fabric Watch group
6
159

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.0.0

Table of Contents