Brocade Communications Systems Brocade 8/12c Reference page 160

Brocade fabric os mib reference supporting fabric os v7.0.0 (53-1002151-01, april 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

6
Switch system group
Object and OID
swAdmStatus
1.3.6.1.4.1.1588.2.1.1.1.1.8
swTelnetShellAdmStatus
1.3.6.1.4.1.1588.2.1.1.1.1.9
swSsn
1.3.6.1.4.1.1588.2.1.1.1.1.10
Flash administration
The next six objects are related to firmware or configuration file management. Due to security restrictions,
firmwaredownload and configuration file upload and download are not supported through SNMP.
swFlashDLOperStatus
1.3.6.1.4.1.1588.2.1.1.1.1.11
140
Access
Description
Read-write
The desired administrative status of the switch. A management
station might place the switch in a desired state by setting this
object accordingly.
Possible values are:
online (1) - Set the switch to be accessible by an external FC
port.
offline (2) - Set the switch to be inaccessible.
testing (3) - Set the switch to run the built-in test.
faulty (4) - Set the switch to a "soft" faulty condition.
reboot (5) - Set the chassis to reboot in 1 second.
fastboot (6) - Set the chassis to fastboot in 1 second. Fastboot
causes the chassis to boot but omit the POST.
When the switch is in faulty state, only two states can be set: faulty
and reboot/fastboot
For the Brocade 3250, 3850, 3900, 8000, 24000, 48000 and DCX
director the testing (3) and faulty (4) values are not applicable.
The possible values for Brocade 300, 5100 and 5300 are either
online (1) or offline (2).
Read-write
The desired administrative status of the Telnet shell.
Setting this value to 1 (terminated), deletes the current Telnet shell
task. When this variable instance is read, it reports the value last
set through SNMP.
This OID is supported in Fabric OS v2.x through v3.x.
This OID is not supported in Fabric OS v4.0 through v4.2.
This OID is supported in Fabric OS v4.3 and later versions.
Possible values are:
unknown (0) - The status of the current Telnet shell task is
unknown.
terminated (1) - The current Telnet shell task is deleted.
By setting it to 1 (terminated), the current Telnet shell task is
deleted. When this variable instance is read, it reports the value
last set through SNMP.
Read only
The soft serial number of the switch.
This variable will return the "ssn" value that is stored in the config
database. If the "ssn" key value pair is not in the config database it
will return WWN of the switch.
Read only
The operational status of the flash. This OID cannot be used for
either Firmwaredownload or Configdownload (cannot be set and is
read only). The value displayed is always "swCurrent (1)".
Fabric OS MIB Reference
53-1002151-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fabric os v7.0.0

Table of Contents