Installing the IPS 4345 and IPS 4360
Table 6-1
Operating power
Steady state/maximum
Total heat dissipation
Output hold-up time
Inrush current
Environment
Temperature
Airflow
Relative humidity
(noncondensing)
Altitude
Acoustic noise
Shock
Vibration
OL-24002-01
IPS 4345 and IPS 4360 Specifications (continued)
372W
730 BTU/hr
20mS
40A
Operating: 23°F to 49°F
(-5°C to 45°C)
Nonoperating: -13°F to -94°F
(-25°C to -70°C)
Front to back
Operating: 0% to 90%
Nonoperating: 10% to 90%
Operating: 0 to 10,000 ft
(0 to 3048 m)
Nonoperating: 0 to 15,000 ft
(0 to 4572 m)
Operating: 64.2
Nonoperating: 70G,4.22m/s
50G,2ms
Operating: 0.41Grms,3Hz to 500Hz
with spectral break points of
0.0005G2/Hz at 10Hz and 200Hz
and 5dB/octave roll-off at each end
Nonoperating: 1.12Grms,3Hz to
500Hz with spectral break points of
0.0065G2/Hz at 10Hz and 100Hz
and 5dB/octave roll-off at each end
Cisco Intrusion Prevention System Appliance and Module Installation Guide for IPS 7.1

Specifications

382W
730 BTU/hr
12mS
40A
Operating: 23°F to 49°F
(-5°C to 45°C)
Nonoperating: -13°F to -94°F
(25°C to -70°C)
Front to back
Operating: 0% to 90%
Nonoperating: 10% to 90%
Operating: 0 to 10,000 ft
(0 to 3048 m)
Nonoperating: 0 to 15,000 ft
(0 to 4572 m)
Operating: 67.9
Nonoperating: 70G,4.22m/s
50G,2ms
Operating: 0.41Grms,3Hz to 500Hz
with spectral break points of
0.0005G2/Hz at 10Hz and 200Hz
and 5dB/octave roll-off at each end.
Nonoperating: 1.12Grms,3Hz to
500Hz with spectral break points of
0.0065G2/Hz at 10Hz and 100Hz
and 5dB/octave roll-off at each end