Password Display – Select the "View guest account passwords" to enable the display of visitor account
passwords in the user list. To reveal passwords, the password field must be added to the "guest_users"
or "guest_edit" view, and the operator profile in use must also have the View Passwords privilege.
Initial Sequence – This field contains the next available sequence number for each username prefix
that has been used. Automatic sequence numbering is used when the value of the
multi_initial_sequence field is set to -1. The username prefix is taken from the multi_prefix field
when usernames are automatically generated using the "nwa_sequence" method. You can edit the values
stored here to change the next sequence numbers that will be used. This is an automatically managed
field; in most situations there is no need to edit it.
Receipt Printing – Select the "Require click to print" option to change the behavior of the receipt page.
When this option is not selected, the default behavior is to provide a drop-down list of print templates
and to open a new window when one is selected:
When "Require click to print" is selected, the receipt page provides a drop-down list of print templates
and a Print link that must be clicked to display the account receipt:
About Guest Network Access – Allows the text displayed to operators on the Guest Manager start
page to be customized, or removed (if a single hyphen "-" is entered).

About Fields, Forms, and Views

A field is a named item of information.
A form is a group of fields that is used to collect information from an operator, whereas a view is a grouping
of fields that is used to display information to an operator.

Business Logic for Account Creation

When guest accounts are created, there are certain rules that must be followed in order to create a valid
account. These rules apply to all accounts, regardless of how the account was created.
The business logic rules that control all guest account creation are described below.
Verification Properties
creator_accept_terms: This field must be set to 1, indicating the creator has accepted the terms of use
for creating the account. If the field is not present or is not set to 1, the visitor account is not created.
password2: If this field is specified, its value must be equal to the "password" field, or else the visitor
account is not created.
auto_update_account: If this field is present and set to a non-zero value, account creation will not fail
if the username already exists – any changes will be merged into the existing account using an update
instead.
Basic User Properties
username: This field is the name for the visitor account and may be provided directly. If this field is not
specified, then use the email address from the email field, and if that is also not specified, then randomly
generate a username (according to the value of the random_username_method and
random_username_length fields).
Amigopod 3.7 | Deployment Guide