Get; Getactiveerrors - Dell PowerEdge VRTX Reference Manual

Chassis management controller version 1.0 for dell poweredge vrtx racadm command line reference
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

The following table describes the firmware update methods supported for each interface.
FW Update Method
Local RACADM
Local RACADM - TFTP
Local RACADM - FTP
Remote RACADM
Remote RACADM-TFTP
Remote RACADM-FTP
Firmware RACADM-TFTP
Firmware RACADM-FTP

get

Description
Synopsis
Input
Example

getactiveerrors

Description
Synopsis
Output
34
Upload the firmware image from the FTP server and start the firmware update.
racadm fwupdate -f 192.168.0.100 fred password123 -d
firmimg.cmc -m cmc-active
Start IOM infrastructure firmware update.
racadm fwupdate -u -m iominf-1
Update firmware on both the CMCs.
racadm fwupdate -g -u -a 192.168.0.100 -d firmimg.cmc -m
cmc-active -m cmc-standby
Saves CMC Event Filter configuration to a file.
NOTE: Currently, these commands are supported only in remote racadm.
racadm get -f <filename>
–f : save event filter configurations to a file.
–Save event filter configurations to a file by using remote racadm.
racadm -r 10.94.161.119 -u root -p calvin get -f config.txt
Displays the active errors in a chassis.
To run this subcommand, you must have the CMC Login User privilege.
racadm getactiveerrors
Module ID
= Chassis
Severity
= Critical
Message
= Power supply redundancy is lost.
-----------------------------------------------------------
--------------------
CMC
No
No
No
Yes
Yes
Yes
Yes
Yes

Advertisement

Table of Contents
loading

Table of Contents