Synopsis
testfeature -f ldap
Description
Synopsis
testtrap
Description
Synopsis
Input
Example
96
Tests the RAC's SNMP trap alerting feature by sending a test trap from iDRAC to a
specified destination trap listener on the network.
To use this subcommand, you must have the Test Alerts permission.
NOTE: Before you execute the testtrap subcommand, make sure that the specified
index in the RACADM cfgAlerting group is configured properly.
racadm testtrap -i <index>
-i — Specifies the index of the trap configuration to be used for the test. Valid values are
from 1 to 4.
Commands for the cfgIpmiPet group:
•
Enable the alert
racadm config -g cfgIpmiPet -o cfgIpmiPetAlertEnable -
i 1
•
Set the destination e-mail IP address
racadm config -g cfgIpmiPet -o
cfgIpmiPetAlertDestIpAddr -i 1 192.168.0.110
•
Verifies if the CMC can acquire CMC, LDAP and
Global Catalog servers FQDN through reverse IP
lookups.
•
Verifies that the CMC principal name matches the
principal name in the uploaded Keytab file.
•
Verifies that the CMC acquires a Kerberos TGT.
•
Acquires user privileges from the Active Directory
server.
•
Checks the time to acquire user privileges with
the allotted time to login.
NOTE: In the event of an error, the command outputs
all tests performed up to and including the test that
failed, and all the error messages.
testfeature -f adkrb -u <username> [-d
<diagnostic-message-level>]
Tests LDAP configuration and operation, and reports
success as each stage of the authentication process
proceeds. After successful completion, this command
prints the CMC privileges assumed by the specified
<
username >.
If a failure occurs, the command stops with an error
message that displays the required corrective action. Use
the optional -d switch to obtain additional diagnostic
information, as needed.
testfeature -f ldap -u <username> -p
<password>
[-d <diagnostic-message-level>]