Getmacaddress - Dell PowerEdge VRTX Reference Manual

Chassis management controller version 1.0 for dell poweredge vrtx racadm command line reference
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Example

getmacaddress

Description
Displays the MAC/WWN addresses for all modules or for a specified module.
To use this subcommand, you must have the CMC Login User privilege.
Synopsis
Input
Example
Display iSCSI MAC addresses for all servers.
racadm getmacaddress -t iscsi
Display iSCSI MAC for server-1.
racadm getmacaddress -m server-1 -t iscsi
Display extra iSCSI MACs for server-1 (if available).
racadm getmacaddress -m server-1 -t iscsi -x
Display MAC for server-1.
racadm getmacaddress -m server-1
40
racadm getmacaddress [-m <module>] [-t iscsi] [-x]
racadm getmacaddress [-a]
module > — Specifies the module whose MAC address you want to view.
-m <
<
module > may be one of the following:
n =1–4
server-n, where
switch-n, where
n =1
-t — Displays the iSCSI MAC addresses for all servers or the specified server if used with -
m option.
-x — Displays the extra MACs (Ethernet or iSCSI) for servers with additional LOM MACs
and must be used with -m option.
-a — Displays the Ethernet and iSCSI MAC/WWN addresses for all iDRAC/LOMs/
mezzanine cards. When FlexAddress is enabled for a particular slot, then the chassis-
assigned MAC/WWN address is displayed.
chassis
CMC active
For CMC:
racadm getled -m server-10
module > < LED state > server-10 Blinking
<
racadm getled -m chassis
module > < LED state > server-10 Not blinking
<
racadm getled -m server-1
module > < LED state > server-1 ON
<
racadm getled -m server-9
module > < LED state > server-9 Extension(1)
<

Advertisement

Table of Contents
loading

Table of Contents