Getpciecfg - Dell PowerEdge VRTX Reference Manual

Chassis management controller version 1.0 for dell poweredge vrtx racadm command line reference
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Synopsis
Example
racadm getpbinfo
[Power Budget Status]
System Input Power
Peak System Power
Peak System Power Timestamp
Minimum System Power
Minimum System Power Timestamp
Overall Power Health
Redundancy
System Input Power Cap
Redundancy Policy
Dynamic PSU Engagement Enabled
System Input Max Power Capacity
Input Redundancy Reserve
Input Power Allocated to Servers
Input Power Allocated to Chassis Infrastructure = 427 W
Total Input Power Available for Allocation
Standby Input Power Capacity
Server Based Power Management Mode
Max Power Conservation Mode
Server Performance Over Power Redundancy
[Chassis Power Supply Status Table]
<Name>
<Presence>
<Output Rated Power>
PS1
Present
1050 W
PS2
Present
1050 W
PS3
Not Present
N/A
PS4
Not Present
N/A
[Server Module Power Allocation Table]
<Slot#> <Server Name> <Power State>
1
SLOT-01
M620
2
SLOT-02
3
SLOT-03
M620
4
SLOT-04

getpciecfg

Description
Displays the FQDD of the PCIe slots and Virtual Adapters, and their mapping information and
properties.
NOTE: To use this subcommand, you must have CMC Login User privilege.
Synopsis
racadm getpciecfg [-c <FQDD>]
Input
-a — Use this option to display the assignment of PCIe slots and Virtual Adapters.
To use this subcommand, you must have the CMC Login User privilege.
racadm getpbinfo
<Power State>
Online
Online
Slot Empty
Slot Empty
<Allocation> <Priority>
OFF
N/A
ON
N/A
= 333 W
= 403 W
= 15:38:01 06/14/2013
= 269 W
= 19:12:27 09/22/2000
= OK
= Yes
= 5000 W
= Power Supply Redundancy
= No
= 2372 W
= 1182 W
= 327 W
= 344 W
= 0 W
= No
= No
= No
<Input Current> <Input Volts>
1.3 A
1.6 A
N/A
N/A
0 W
1
N/A
1
327 W
1
N/A
1
115.5 V
116.0 V
N/A
N/A
<Blade Type>
PowerEdge
N/A