Safety and Homologation Statements

Safety and Homologation Statements

CE Mark
The "CE" mark affixed to this equipment means that the unit complies with the 1999/5/EC
(R&TTE), 89/336/EEC (EMC) and 72/23EEC (LVD) Directives.
Declaration of Conformity
The Declaration of Conformity (DoC) for the IP400 Office products is contained with in the CD
accompanying the products.
This warning symbol is found on the base of IP403, IP406 V2, IP412 units and on the base of the
IP400 Digital Station 80W Lump-in-Line PSU. Refer to Trunk Interface Modules for information
concerning which Trunk Interface module variants are fitted in which country.
The Avaya IP400 Office units are intended to be installed by 'Service Personnel' and it is the
responsibility of the Service Personnel to ensure that all subsidiary interconnected equipment is
wired correctly and also meet the safety requirements of IEC60950 or UL60950 where applicable.

Lithium Batteries

A lithium battery is fitted to the real time clock on the IP403, IP406V2 and IP412 mother boards.
The Lithium battery must only be replaced by Avaya personnel or authorized representatives.
There is a danger of explosion if the battery is incorrectly replaced. Replace only with the same
or equivalent type recommended by the manufacturer. Dispose of used batteries according to the

Lightning Protection/Hazard Symbols

Lightning protectors
The buildings lightning protectors must be verified as follow:
1. Check the lightning protectors, at the trunk cable entry point to the building housing the Avaya IP
Office, paying special attention to the lightning protection grounding. Report any problems, in
writing, to the telephone company.
2. Equipment that is designed to be connected using internal wiring is typically not lightning
protected. Hence, Avaya IP Office extension cabling must not leave the building. For
installations where telephones and/or other standard (tip/ring) devices are installed in another
building then lightning protection is required (see Out of Building Telephone Installations).
Hazard Symbol
The shock hazard symbol is intended to alert personnel to electrical hazard or equipment
damage. The following precautions must also be observed when installing telephone equipment:
1. Never install telephone wiring during a lightning storm.
2. Never install telephone jacks in wet locations unless the jack is specifically designed for
wet locations.
3. Never Touch uninsulated telephone wires or terminals unless the telephone line has
been disconnected at the network interface.
4. Always use caution when working with telephone lines.
Installation Manual
IP Office 3.0
WARNING
WARNING
manufacturer's instructions.