Toshiba Strata CIX Programming Manual page 79

Application release 5
Hide thumbs Also See for Strata CIX:
Table of Contents

Advertisement

Table 3-12
Parameter Definitions (continued)
Parameter
sys_max_guest_box
sys_max_prompt
sys_max_sec_code_len
sys_max_silence
sys_maximum_box_length
sys_min_guest_box
sys_min_sec_code_len
sys_minimum_message_length
sys_minimum_record_length
Strata CIX Voice Mail Programming
Last mailbox number that can be used when creating a Guest Mailbox.
When used with the sys_min_guest_box parameter, they limit the number of
Guest Mailboxes that can be created.
Example: If this value is 90200, then the last Guest Mailbox that can be
created is Mailbox 90200.
Possible values: valid mailbox number larger than the sys_min_guest_box
parameter setting
Default: 90200
Number of times a prompt should repeat until deciding to hang up.
Possible values: 1~9
Default: 3
Controls the maximum length security code that voice mail accepts as a new
security code when a user attempts to change it from a telephone.
Note Value must be greater than or equal to the minimum length security
code (i.e., sys_min_sec_code_len).
Possible values: 1~16
Default: 16
Specifies maximum number of milliseconds in silence before recording is
terminated.
Default: 5000 ms
Maximum number of digits voice mail expects in the case that the maximum
number of digits voice mail expects for the beginning digit of that mailbox
number is not defined.
Default: 5
Starting mailbox number that may be used when creating a Guest Mailbox.
When used with the sys_max_guest_box parameter, they limit the number of
Guest Mailboxes that can be created.
Examples: If this value is 90000, then the first Guest Mailbox that is created
is Mailbox 90000. The second guest has Mailbox 90001, etc.
Possible values: valid mailbox number smaller than sys_max_guest_box
parameter setting
Default: 90000
Controls the minimum length security code that voice mail accepts as a new
security code when a suer attempts to change it from a telephone.
Note Value must be less than or equal to the maximum length security code
(i.e., sys_max_sec_code_len).
Possible values: 1~16
Default: 3
Minimum message length in milliseconds for the system to be able to
recognize the message.
Default: 1000 ms
Minimum record length in milliseconds.
Default: 100 ms