Managing Switch User Accounts
Global user account lockout defaults are as follows:
Parameter Description
Length of time during which failed
login attempts are counted.
Length of time a user account
remains locked out of the switch
before the account is automatically
unlocked.
Maximum number of failed login
attempts allowed during the lockout
window time period.
OmniSwitch AOS Release 7 Switch Management Guide
Command
user lockout-window
user lockout-duration
user lockout-threshold
March 2011
User Account Defaults
Default
0—failed login attempts
are never aged out.
0—account remains
locked until manually
unlocked
0—no limit to the num-
ber of failed login
attempts
page 6-3