(2) Connecting the power source cord
• Voltage specifications
Rating label
• Connecting single phase 200V, 220V, 230V and 240V
Light blue
Table
Control box
Green/Yellow
Brown
• Connecting three phase 200V, 220V and 240V
White
Table
Control box
Green/Yellow
Black
Black
Red
1. Never use under the wrong voltage and phase.
2. When changing the voltage, refer to the item of "Changing the voltage of 100 /
200V".
Voltage caution seal
Voltage indication seal (3-phase type only)
Light blue
Green/Yellow
Plug
Brown
Power switch
White
Green /
Yellow
Plug
Red
Power switch
– 5 –
Power source specifications are indicated on the
voltage ndcaton seal. (3-phase type only)
For other type machines, power source specifica-
tons are ndcated on the voltage cauton seal and
the ratng label.
Connect the cord in accordance with the specifica-
tons.
Power source cord
Power source cord
AC200 V
Brown
AC220 V
Light
AC230 V
blue
AC240 V
Green/
GND
Yellow
White
AC200 V
Black
AC220 V
AC240 V
Red
Green /
GND
Yellow