SATO CL408 Programming Reference Manual page 120

E/pro programming reference
Hide thumbs Also See for CL408:
Table of Contents

Advertisement

QR CODE
FUNCTION
Specifies QR Code of 2D code.
FORMAT
<ESC>BQ (Manual setting)
<ESC>BQ (Auto setting)
Place anywhere after <ESC>V but before <ESC>Q.
EXAMPLE
<ESC>A
<ESC>H0100<ESC>V0100<ESC>BQ3010,112345
<ESC>Q1
<ESC>Z
OUTPUT
(4-42)
NOTES
Carry out XOR logic operation of all the partitioned print data of the QR code and then, specify this
operation data in hexadecimal character. This is referred to as "Parity Data".
When the character mode is set to other than binary mode, it is not necessary to set the data number
parameter.
Refer to Appendix: Reference Tables 23, 24, 25, and 26 for additional information.
E/Pro Programming Reference
Unit 4: Standard Command Codes
a
= Error correction level
1: 7% high density
2: 15% standard
3: 30% high reliability
4: 25%
b
= Concentration mode
0: Normal mode
1: Concentration mode
c
= Cell size (01 to 32)
d
= Number of partitions by concentration mode (01 to 16)
e
= Sequential number partitioned by concentration mode (01 to 16)
f
= Concentration mode parity data (00 to ff)
g
= Character mode
1: Number mode
2: Alphanumeric mode
3: Binary mode
h
= Data number (0001 to 7366)
n
= Data
4-68
PN: 9001096E