The following example permanently changes the port 1 administrative state:
SANbox #> admin start
SANbox (admin) #> config edit
SANbox (admin-config) #> set config port 1
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Configuring Port Number:
------------------------
AdminState
LinkSpeed
PortType
SymPortName
ALFairness
DeviceScanEnable (True / False)
ForceOfflineRSCN (True / False)
ARB_FF
InteropCredit
FANEnable
AutoPerfTuning
LCFEnable
MFSEnable
VIEnable
MSEnable
NoClose
IOStreamGuard
PDISCPingEnable
Finished configuring attributes.
This configuration must be saved (see config save command) and
activated (see config activate command) before it can take effect.
To discard this configuration use the config cancel command.
SANbox (admin-config) #> config save
SANbox (admin-config) #> config activate
59263-01 A
1
(1=Online, 2=Offline, 3=Diagnostics, 4=Down)
(1=Gb/s, 2=2Gb/s, 4=4Gb/s, 8=8Gb/s, A=Auto)
(GL / G / F / FL / Donor)
(string, max=32 chars)
(True / False)
(True / False)
(decimal value, 0-255)
(True / False)
(True / False)
(True / False)
(True / False)
(True / False)
(True / False)
(True / False)
(Enable / Disable / Auto)
(True / False)
6 – Port Configuration
Modifying Port Operating Characteristics
[Online] offline
[Auto
[GL
[Port1 ]
[False ]
[True
[False ]
[False ]
[0
[True
[False ]
[False ]
[False ]
[False ]
[True
[False ]
[Disable]
[True
]
]
]
]
]
]
]
6-7