Nortel BM450 Troubleshooting Manual page 23

Table of Contents

Advertisement

Figure 3 DTM LEDs
Power LED
Status LED
In service LED
Loopback test LED
Receive LEDs
Transmit LEDs
The table
DTM LED functions
Table 4 DTM LED functions
LED
Status
Power
Status
In service
Flashing
Loopback test
On
Receive alarm
On
Receive error
On
Transmit alarm
On
Transmit error
On
All LEDS
Flashing
on page 23 describes the functions of the DTM LEDs.
Descriptions
See
"Media bay module LEDs (expansion units only)"
See
"Media bay module LEDs (expansion units only)"
The T1, ETSI, or PRI trunks are out of service because a loopback test is
running or the DTM is initializing.
A continuity loopback test is running.
A problem with the received digital transmission. This half-duplex link does
not work.
A small error as a result of degraded digital transmission. Possible causes are
an ohmic connection, water ingress, or too long a loop.
The DTM cannot transmit. The DTM sends an alarm indication signal (AIS) to
the terminating switch. This half-duplex link does not work.
The DTM is sending a remote alarm indication (RAI) carrier failure alarm
(CFA) to the terminating switch. If the transmit alarm is not on, this error
indicates a far-end or cable problem.
The DTM is initializing.
Chapter 3 Hardware Troubleshooting
for details.
for details.