HP Surestore 64 - Director Switch Installation Manual page 113

Fw 05.01.00 and sw 07.01.00 director 2/64 installation guide (aa-rsngc-te/958-000289-001, june 2003)
Hide thumbs Also See for Surestore 64 - Director Switch:
Table of Contents

Advertisement

Use these steps to fabric-attach the director and create an ISL:
1. Verify that the director is defined via HAFM. See
2. Verify that the preferred domain ID for the director is unique and does not
3. Verify that the R_A_TOV and E_D_TOV values for the director are identical
4. Route a multi-mode or single-mode fiber-optic cable (depending on the ISL
5. At the Products View page, click the Director 2/64 icon. The Hardware
6. Click the UPM card graphic supporting the E_Port connection to open the
7. Click the E_Port connector to open the Port Properties dialog box, as shown
8. Verify that the Link Incident field displays None and the Segmentation
Director 2/64 Installation Guide
Manage the
Director" on page 80.
conflict with the ID of another director or switch participating in the fabric.
To change the domain ID, see
to the values for all directors and edge switches participating in the fabric.
distance between directors) between customer-specified E_Ports of both
directors.
View page for the selected director displays.
Port Card View page.
in
Figure
55.
Reason field is blank or displays N/A. If an ISL segmentation or other
problem is indicated, consult the HP StorageWorks Director 2/64 Service
Manual to isolate the problem. If no problems are indicated, installation is
complete.
Installing and Configuring the Director 2/64
"Enabling HAFM to
"Configure Fabric
Parameters" on page 93.
113