HP Surestore 64 - Director Switch Installation Manual page 100

Fw 05.01.00 and sw 07.01.00 director 2/64 installation guide (aa-rsngc-te/958-000289-001, june 2003)
Hide thumbs Also See for Surestore 64 - Director Switch:
Table of Contents

Advertisement

Installing and Configuring the Director 2/64
Figure 44: Configure SNMP dialog box
2. To enable transmission of trap messages to configured SNMP management
3. Click Activate to save the information and close the dialog box.
100
a. For each trap recipient to be configured, type a community name of 32 or
fewer alphanumeric characters in the associated Community Name field.
The community name is incorporated in SNMP trap messages to ensure
against unauthorized viewing or use.
b. Click the check box in the Write Authorization column to enable or
disable write authorization for the trap recipient (default is disabled). A
check mark in the box indicates write authorization is enabled. When the
feature is enabled, a management workstation user can change the HAFM
server's sysContact, sysName, and sysLocation SNMP variables.
c. Type the IP address or DNS host name of the trap recipient (SNMP
management workstation) in the associated Trap Recipient field. Use 64
or fewer alphanumeric characters. Hewlett-Packard recommends using
the IP address.
d. Type a decimal user datagram protocol (UDP) port number in the
associated UDP Port Number field. (This number is commonly 162.)
workstations, click Enable Authorization Traps. A check mark displays in
the box when transmission is enabled.
Director 2/64 Installation Guide