Monitoring The Power Supply Status - HP StorageWorks MSA 2/8 - SAN Switch User Manual

Hp storageworks fabric os procedures v3.1.x/4.1.x user guide (aa-rs23c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

Diagnostics and Status
Note:
switch. For more information, refer to the particular hardware reference manual for
your switch.

Monitoring the Power Supply Status

To display the power supply status of a switch:
1. Log into the switch as the admin user.
2. Enter the psshow command at the command line. The possible values for
After the status line, a power supply identification line may be shown. If present,
this line contains manufacture date, part numbers, serial numbers, and other
identification information.
The following example displays the power supply status using the psshow
command.
Example:
switch:admin> psshow
Power Supply #1 is OK
DELTA DPS-1001AB-1E 23000000601 S1
Power Supply #2 is OK
DELTA DPS-1001AB-1E 23000000601 S1
Power Supply #3 is absent
Power Supply #4 is OK
DELTA DPS-1001AB-1E 23000000601 S1
switch:admin>
188
The number of fans and valid range for RPMs varies depending on the type of
power supply status are:
OK - Power supply present and functioning correctly.
absent - Power supply not present.
faulty - Power supply present but faulty (no power cable, power switch
turned off, fuse blown, or other internal error).
IXD0111000089
IXD0111000132
IXD0111000117
Fabric OS Procedures Version 3.1.x/4.1.x User Guide