Error 01
--------
0x271 (fabos): Nov 24 15:04:06
Switch: 1, Info EM-BOOT, 4, Restart reason: Failover
switch:admin>
Displaying the Error Log With Page Breaks
To display the error log:
1. Log into the switch as the admin user.
2. At the command line, enter the errshow command.
Example:
switch:admin> errshow
Error 497
--------
0x4a5 (fabos): Oct 03 04:40:14
Switch: 0, Info TRACK-LOGIN, 4, Successful login
Type <CR> to continue, Q<CR> to stop: q
Clearing the Switch Error Log
To clear the error log for a particular switch instance:
1. Log into the switch as the admin user.
2. Enter the errclear -p command to clear only the persistent errors. The
or
Fabric OS Procedures Version 3.1.x/4.1.x User Guide
error log in RAM is not cleared.
Enter the errclear command (with no operands) to clear the RAM
memory and remove persistent messages from the default errShow
display.
Diagnostics and Status
167