Procedures For Updating The Core Pid Format; Basic Update Procedures - HP StorageWorks MSA 2/8 - SAN Switch User Manual

Hp storageworks fabric os procedures v3.1.x/4.1.x user guide (aa-rs23c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

Updating Switches to the Core PID Addressing

Procedures for Updating the Core PID Format

The following sections present basic procedures for update the Core PID format
and detailed procedures for HP/UX and AIX.

Basic Update Procedures

This process should be executed as part of the overall online or offline update
process. However, it may be implemented in a stand-alone manner on a
non-production fabric on a switch that has not yet joined a fabric.
1. Ensure that all switches in the fabric are running Fabric OS versions that
Note:
Switch PID Format enabled, so it is not necessary to perform the PID format change on
these switches.
2. Telnet into one of the switches in the fabric.
3. Disable the switch by entering the switchdisable command.
4. Enter the configure command (the configure prompts display
5. Enter "y" after the "Fabric parameters" prompt.
6. Enter "1" at the "Core Switch PID Format" prompt.
7. Complete the remaining prompts or press Ctrl+D to accept the remaining
8. Repeat steps 2 through 7 for the remaining switches in the fabric.
9. Re-enable the switch by entering the switchenable command.
154
support the new addressing mode. The recommended firmware versions are:
2.6.0c or later for StorageWorks 1 Gb SAN switches, 3.0.2g or later for SAN
Switch 2/8 EL and SAN Switch 2/16 switches, and 4.0.2x or later for SAN
Switch 2/32 and Core Switch 2/64 switches.
All switches running any version of Fabric OS 4.x are shipped with the Core
sequentially).
settings without completing all the prompts.
Fabric OS Procedures Version 3.1.x/4.1.x User Guide

Advertisement

Table of Contents
loading