Firmware Download
5. Enter the User name and the Host IP (ftp server).
6. Answer the prompts as they appear. The following are the recommended
Example
7
Full Install (Otherwise upgrade only) [Y]: y
Do Auto Commit after reboot [Y]: Y
Reboot system after download [N]: Y
7. Wait for the firmware download to complete. Use the
Example
FirmwareDownload has started on Active CP. It may take up to 10 minutes.
Please use firmwareShow to see the firmware status.
switch:admin> firmwareshow
Local CP (Slot 6, CP1): Active
Primary partition:
Secondary Partition:
Remote CP (Slot 5, CP0): Standby
Primary partition:
Secondary Partition:
switch:admin>
8. (Optional) Repeat the firmware download procedure on the second CP when
86
responses.
— Answer Y (yes) to Full Install. Answering no to this prompt can cause
problems with the CP.
— Answer Y (yes) to Auto Commit if you want the firmware to be
commited automatically after download. If you answer no, you must
manually enter the firmwarecommit command.
— Answer Y (yes) to reboot the system after download if you want to
enable auto-reboot.
firmwareDownloadStatus command in a new session to check the
status.
the process is completed on the first CP.