Check The Simple Name Server (Sns); Check For The Device In The Sns - HP StorageWorks MSA 2/8 - SAN Switch User Manual

Hp storageworks fabric os procedures v3.1.x/4.1.x user guide (aa-rs23c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

Troubleshooting

Check the Simple Name Server (SNS)

Check for the Device in the SNS

1. Enter the nsShow command on the switch to which the device is attached.
Example:
The Local Name Server has 9 entries {
Type Pid
COS
*N
021a00;
Fabric Port Name: 20:0a:00:60:69:10:8d:fd
NL
051edc;
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee0;
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee1;
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee2;
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee4;
FC4s: FCP [SEAGATE ST318304FC
200
PortName
2,3;20:00:00:e0:69:f0:07:c6;10:00:00:e0:69:f0:07:c6; 895
3;21:00:00:20:37:d9:77:96;20:00:00:20:37:d9:77:96; na
3;21:00:00:20:37:d9:73:0f;20:00:00:20:37:d9:73:0f; na
3;21:00:00:20:37:d9:76:b3;20:00:00:20:37:d9:76:b3; na
3;21:00:00:20:37:d9:77:5a;20:00:00:20:37:d9:77:5a; na
3;21:00:00:20:37:d9:74:d7;20:00:00:20:37:d9:74:d7; na
NodeName
0005]
0005]
0005]
0005]
0005]