Troubleshooting
Check the Simple Name Server (SNS)
Check for the Device in the SNS
1. Enter the nsShow command on the switch to which the device is attached.
Example:
The Local Name Server has 9 entries {
Type Pid
COS
*N
021a00;
Fabric Port Name: 20:0a:00:60:69:10:8d:fd
NL
051edc;
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee0;
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee1;
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee2;
FC4s: FCP [SEAGATE ST318304FC
Fabric Port Name: 20:0e:00:60:69:10:9b:5b
NL
051ee4;
FC4s: FCP [SEAGATE ST318304FC
200
PortName
2,3;20:00:00:e0:69:f0:07:c6;10:00:00:e0:69:f0:07:c6; 895
3;21:00:00:20:37:d9:77:96;20:00:00:20:37:d9:77:96; na
3;21:00:00:20:37:d9:73:0f;20:00:00:20:37:d9:73:0f; na
3;21:00:00:20:37:d9:76:b3;20:00:00:20:37:d9:76:b3; na
3;21:00:00:20:37:d9:77:5a;20:00:00:20:37:d9:77:5a; na
3;21:00:00:20:37:d9:74:d7;20:00:00:20:37:d9:74:d7; na
NodeName
0005]
0005]
0005]
0005]
0005]
Fabric OS Procedures Version 3.1.x/4.1.x User Guide
TTL(sec)