HP StorageWorks MSA 2/8 - SAN Switch User Manual page 85

Hp storageworks fabric os procedures v3.1.x/4.1.x user guide (aa-rs23c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

Example
switch:admin> hashow
Local CP (Slot 5, CP0): Active
Remote CP (Slot 6, CP1): Standby, Healthy
HA enabled, Heartbeat Up, HA State in sync
This message varies, depending on the version of firmware that is currently
installed.
3. Telnet in to the Active CP.
Example
Telnet 192.168.174.91
4. Use the firmwaredownload -s command to download a new version
The -s option allows a user to upgrade to a single CP on a Core Switch 2/64
switch, select a full-install, auto-reboot, and auto-commit. Place a space between
the command and the option.
Example
switch: admin> firmwaredownload -s
Server Name or IP Address: 10.255.255.115
User Name:Admin
File Name:
Password:
Full Install (Otherwise upgrade only) [Y]: n
Do Auto Commit after reboot [Y]: y
Reboot system after download [N]: y
Fabric OS Procedures Version 3.1.x/4.1.x User Guide
of the firmware to the Standby CP.
Firmware Download
85