Toshiba TMP92CM22FG TLCS-900/H1 Series Manual page 172

Toshiba original cmos 32-bit microcontroller
Table of Contents

Advertisement

(3) Data format
Format of transmission/receiving must set to data length 8-bit, without parity bit, 1 bit
of stop bit.
Any other settings don't guarantee the normal operation.
(4) SFR
Figure 3.9.27 shows the control register SIRCR. If change setting this register, must
set it after set operation of transmission/receiving to disable (Both <TXEN> and
<RXEN> of this register should be clear to 0).
Any changing for this register during transmission or receiving operation doesn't
guarantee the normal operation.
The following example describes how to set this register:
1)
SIO setting
2)
LD (SIRCR), 07H
3)
LD (SIRCR), 37H
4)
Transmission/receiving ; The modem operates as follows:
(5) Notes
1.
Making baud rate when using IrDA
In baud rate during using IrDA, must set "01" to SC0MOD0<SC1:0> in SIO by
using baud rate generator.
TA0TRG, f
2.
Output pulse width and baud rate generator during transmission IrDA
As the IrDA 1.0 physical layer specification, the data transfer speed and
infra-red pulse width is specified.
Table 3.9.4 Specification of Transfer Rate and Pulse Width
Transfer
Modulation
Rate
2.4 kbps
RZI
9.6 kbps
RZI
19.2 kbps
RZI
38.4 kbps
RZI
57.6 kbps
RZI
115.2 kbps
RZI
The infra-red pulse width is specified either baud rate T × 3/16 or 1.6 μs (1.6 μs is
equal to T × 3/16 pulse width when baud rate is 115.2 kbps).
The TMP92CM22 has function which is selectable the transmission pulse width
either 3/16 or 1/16. But T × 1/16 pulse width can be selected when the baud rate is
equal or less than 38.4 kbps only. When 57.6 kbps and 115.2 kbps, the output pulse
width should not be set to T × 1/16.
; Set SIO side.
; Set receiving effect pulse width to 16X.
; TXEN, RXEN enable the transmission and receiving.
, SCLK0 input of except for it can not using.
IO
Transfer Rate
Minimum of
Tolerance
Pulse Width
(% of Rate)
± 0.87
1.41 μs
± 0.87
1.41 μs
± 0.87
1.41 μs
± 0.87
1.41 μs
± 0.87
1.41 μs
± 0.87
1.41 μs
92CM22-170
SIO0 starts transmitting.
IR receiver starts receiving.
Typical of Pulse
Width 3/16
78.13 μs
19.53 μs
9.77 μs
4.88 μs
3.26 μs
1.63 μs
TMP92CM22
Maximum of
Pulse Width
88.55 μs
22.13 μs
11.07 μs
5.96 μs
4.34 μs
2.23 μs
2007-02-16