OPERATIONS AND TIMING
3. Operation of Fixing Assembly Tem-
perature Control System
Power switch

Main motor(M1);
Scanner cooling fan(FM2)
Exhaust fan(FM1)
Fixing roller heater(H1)
Oil application solenoid(SL6)
WAIT indicator
(COPY START key indicator)
190˚C
180˚C
170˚C
155˚C
115˚C
90˚C
50˚C
3–90
COPY START key
115˚C
ON
(TH2;175˚C)
ON
(50˚C)
(TH1;155˚C)
WMUP WMUPR
STBY

Slow



Glows green
Figure 3-443
COPYRIGHT © 1998 CANON INC.
SCFW
SCRV
SCFW
Glows orange
; Actual temperature(Paper area)
; TH1/TH2 control temperature(Control area)