DS1 Circuit Pack Reports
Table 6-9. Field Descriptions for Circuit Pack Reports
Field
Location
Code
Suffix
Vintage
Type of Circuit Pack
PORTS
Assigned
Unassigned
TTI
Total
You can click on the fields in an alarm report to display screens with more
information about the alarm. See How to Get More Report Information.
DS1 Circuit Pack Reports
DS1 circuit pack reports display all DS1 circuit packs that are administered by
the PBX or that are physically present in the PBX.
You can also create custom reports on the Report Builder screen.
Double click on the following icons for more information about DS1 circuit pack
reports:
Description
The circuit pack's cabinet, carrier, and slot.
Click on this field to display more information.
The product code for the circuit pack.
The suffix of the circuit pack.
One of the following:
The vintage of the circuit pack.
The highlighted word CONFLICT; if there
is a mismatch between the circuit pack's
administration and type.
The external name of the circuit pack.
A heading that groups the following port
fields.
The number of assigned ports on the circuit
pack.
The number of unassigned ports on the
circuit pack.
The number of TTI (Terminal Translation
Initialization) ports on the circuit pack. TTI
ports are initialized from the terminal instead
of the administration screen.
The total number of ports on the circuit pack.
6-9
Issue 2 April 1996
Need help?