The Configuration Manager
Table 6-5. Report Heading
Data
# Circuit
Packs of #
Types
Application
Name
Report Title
Switch Name
Table 6-6. Fields on the Circuit Pack Inventory Report
Field
Count
Code
Suffix
Vintage
Type of Circuit Pack
How to Save Inventory Reports
To save an alarms or error report to a file:
1. Select Options
Result: Fault Management prompts you for a file name.
2. Enter the name of the file, including the path where you want the file
saved. If you do not enter a path, the system saves the file in the directory
you were in when you started the NMS.
3. Click on Save.
6-6
Issue 2 April 1996
Description
The total number of circuit packs and the total number of
types of circuit packs
DEFINITY G3 Fault Management
Circuit Pack Inventory
The name of the PBX as it appears on the NMS when the
PBX is administered as a node on the network.
Description
How many of that type of circuit pack are on
the PBX
The ID code for each circuit pack on the PBX
The suffix for the circuit pack
The vintage or release of the circuit pack
The type of circuit pack
à
Save Report.
Need help?