AT&T MERLIN LEGEND Release 2.0 Equipment And Operations Manual page 82

Hide thumbs Also See for MERLIN LEGEND Release 2.0:
Table of Contents

Advertisement

Hardware Components
Table 2-1. - Continued
Module
Line/Trunk Type
400EM
Tie trunk
400 GS/LS/TTR
LS or GS
and TTR
2
408
LS
408 GS/LS
LS or GS
3
-MLX
408 GS/LS
LS or GS
2
8 0 0
LS
800 DID
DID
800 GS/LS
LS or GS
Notes:
1.
The system software recognizes the OPT moduleas a 012 module, Even though the OPT module only
has 8 jacks, it uses 12 ports of capacity, thereby decreasing overall station capacity by four stations for
every OPT module.
2.
Although these MERLIN II modules are supported, the following are the recommended modules for the
system. 400 GS/LS, 408 GS/LS, 800 GS/LS, 408 GSLS-MLX.
3
This module is not compatible with Releases 1.0 and 1.1: it applies to Release 2.0 and later.
2-8 Control Unit
Station Type
Capacity: 4 tie trunks
Method of Completion: automatic or dial-repeating start;
immediate-start, wink-start, or delay-dial-start
Signaling: E&M type 1S, type 1C, type 5
PFT telephone (GS
Capacity: 4 lines/trunks, 4 TTRs, 1 PFT telephone
button needed for PFT
Signaling: loop-start or GS, optioned per port
telephone)
Analog multiline
Capacity: 4 lines/trunks, 8 stations, 1 PFT telephone
telephone; CMS; PFT
Station signaling: analog multiline telephone (40 kbps)
telephone
Line/trunk signaling: loop-start line/trunk; analog voice
Loop range: 1000 feet (305 meters), For In-Range Out-of-Building
service, use analog IR0B protectors: over 1000 feet (305 meters),
use OPRE.
Analog multiline
Capacity: 4 lines/trunks, 8 stations, 1 PFT telephone
telephone; CMS; PFT
Station signaling: analog multiline telephone (40 kbps)
telephone (GS button
Line/trunk signaling: Ioop-start or ground-start line/trunk (optional
needed for PFT
per port); voice
telephone)
Loop range: 1000 feet (305 meters). For In-Range Out-of-Building
service, use analog IROB protectors; over 1000 feet (305 meters),
use OPRE.
MLX telephone; digital
Capacity: 4 lines/trunks, 1 PFT telephone, 8 digital stations, each
data device (such as
with 1 or 2 endpoints (each endpoint is assigned an individual
7500B Data Module)
extension number), including the following station types:
digital voice only
digital voice with Voice Announce to Busy feature
digital voice and digital data (via the 7500B Data Module)
digital voice and MFM
digital data only (7500B Data Module)
Signaling: BRI S/T protocol (two 64-kbps B-channels, one 16-kbps
D-channel) on a passive bus
Power: 48 VDC phantom power to telephone; 48 VDC over a
separate pair (7-8) to a DSS console
Loop range: 1000 feet (305 meters) For In-Range Out-of-Building
service, use MLX IROB protectors; over 1000 feet (305 meters), use
OPRE.
Capacity: 8 lines/trunks, 2 PFT telephones
PFT telephone
Signaling: loop-start
Capacity. 8 lines/trunks, 2 TTRs
Protocol: incoming calls only, 2-way (one-pair) fixed impedance to
DID trunks; no outgoing calls
Signaling: loop-reverse battery; wink-start or immediate-start:
accepts touch-tone dialing
PFT telephone (GS
Capacity: 8 lines/trunks, 2 PFT telephones
button needed for PFT
Signaling: loop-start or ground-start
telephone)
Specifications

Advertisement

Table of Contents
loading

Table of Contents