Brother BE-1204B Instruction Manual page 171

12 needle embroidery machine stand-alone type
Hide thumbs Also See for BE-1204B:
Table of Contents

Advertisement

Code
Error Messages
Needle bar case motor
E-D5
overcurrent
E-D6
Jump motor overcurrent
Temperature rise error
E-D7
Clean the fan filter
Temperature sensor
E-D8
abnormal
X-axis pulse motor
E-E1
overcurrent stop
Turn off the power
Y-axis pulse motor
E-E2
overcurrent stop
Turn off the power
E-E3
Exhaust fan motor stop
E-E4
Hook motor error
E-E5
ERROR E5
E-E6
ERROR E6
E-E7
ERROR E7
E-E8
ERROR E8
E-E9
ERROR E9
E-EA
ERROR EA
E-EB
ERROR EB
E-EC
ERROR EC
E-ED
ERROR ED
E-EE
ERROR EE
E-EF
ERROR EF
E-F1
ERROR F1
E-F2
ERROR F2
E-F3
ERROR F3
E-F4
ERROR F4
E-F5
ERROR F5
E-F6
ERROR F6
E-F7
ERROR F7
E-F8
ERROR F8
Error
Needle bar case motor overcurrent
Jump motor overcurrent
The temperature of the heat sink
on the drive PCB rose excessively
Temperature sensor abnormal
X-axis pulse motor overcurrent
stop
Y-axis pulse motor overcurrent
stop
Cooling fan motor stop A Press R.
Lower shaft communication error
Over-run error during interfacing to
main PCB CPU
Framing error during interfacing to
main PCB CPU
Parity error during interfacing to
main PCB CPU
Receiving time up error during
interfacing to main PCB CPU
Send/Receive inconsistent error
during interfacing to main PCB
CPU
ACK code receiving error during
interfacing to main PCB CPU
Send/Receive ID code error during
interfacing to main PCB CPU
Send data checksum error during
interfacing to main PCB CPU
Data empty error during interfacing
to main PCB CPU
Abnormal data received in the
inner-machine communication
Receiving error on interface
Receive time up error
Request-to-waiting time up error
Request-to-receive time up error
Receive command error
NACK code receiving error
Data requested for needle position
can not be returned.
It is not receive command for the
request one.
PRE code error
BE-1204B-BC • BE-1206B-BC
Measures
Turn OFF the power. The possible causes for this
error are, troubles of the needle bar case motor,
troubles of the main PCB, and troubles of the
drive PCB.
Turn OFF the power. The possible causes for this
error are troubles of the jump motor and troubles
of the head PCB.
Turn OFF the power and check if the fan filter has
any clogging.
Turn OFF the power. The possible causes for this
error are troubles of the thermistor and troubles
of the drive PCB.
Turn OFF the power and ON once. If the same
error occurs again, the pulse motor or the drive
PCB is faulty.
Turn OFF the power and check the fan harness.
Turn OFF the power again. If the same error
occurs again, the fan or the power PCB is faultly.
This is not displayed in this model.
This is not usually displayed.
Chapter 9 Error code list
9-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Be-1204cBe-1204b-bcBe-1206b-bc

Table of Contents