connUnitSensorStatusChange
Enterprise
Variables
Description
Note
connUnitSensorStatus.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.7 = failed(5)
connUnitPortStatusChange
Enterprise
Variables
Description
Note
connUnitPortStatus.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.29 = ready(3)
connUnitPortState.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.29 = online(2)
connUnitPortName.16.0.0.96.105.144.109.136.0.0.0.0.0.0.0.0.29 = test
256 FibreAlliance MIB objects
fcmgmt
connUnitSensorStatus
Overall status of the connectivity unit has changed.
This trap is generated whenever the status of the sensors (like fan, power supply,
temperature) present in the connectivity unit changes.
Sample trap output for Fabric OS 4.4.0:
See the HP StorageWorks Fabric OS 5.x Fabric Watch administrator guide for
information on configuring thresholds that generate these traps.
fcmgmt
connUnitPortStatus, connUnitPortState
Overall status of the connectivity unit changed. Recommended severity level (for filtering):
alert.
This trap sends the instance of connUnitPortName as part of the trap; the instance string is
NULL, if the port name is not defined for the specified port.
Sample trap output for Fabric OS 4.4.0:
See the
swFCPortScn
for more information.