fcFxPortPhysModuleIndex

OID
Description

fcFxPortPhysFxPortIndex

OID
Description

fcFxPortPhysAdminStatus

OID
Description

fcFxPortPhysOperStatus

OID
Description

fcFxPortPhysLastChange

OID
Description
1.3.6.1.3.42.2.1.2.3.1.1
Identifies the module containing the Fx_Port for which this entry contains information.
1.3.6.1.3.42.2.1.2.3.1.2
Identifies the Fx_Port within the module. This number ranges from 1 to the value of
fcFeModulePortCapacity for the associated module. The value remains constant for the
identified Fx_Port until the module is reinitialized.
1.3.6.1.3.42.2.1.2.3.1.3
The desired state of the Fx_Port:
• online (1): Place port online.
• offline (2): Take port offline.
• testing (3): Initiate test procedures.
A management station might place the Fx_Port in a desired state by setting this object
accordingly. The testing state (3) indicates that no operational frames can be passed.
When an FE initializes, all Fx_Ports start with fcFxPortPhysAdminStatus in the offline state
(2). As the result of either explicit management action or per configuration information
accessible by the FE, fcFxPortPhysAdminStatus is then changed to either the online (1) or
testing (3) state, or remains in the offline state (2).
1.3.6.1.3.42.2.1.2.3.1.4
The current operational status of the Fx_Port:
• online (1): Login might proceed.
• offline (2): Login cannot proceed.
• testing (3): Port is under test.
• link-failure (4): Failure after online/testing.
The testing state (3) indicates that no operational frames can be passed. If
fcFxPortPhysAdminStatus is offline (2), then fcFxPortPhysOperStatus should be offline (2). If
fcFxPortPhysAdminStatus is changed to online (1), then fcFxPortPhysOperStatus should
change to 1 (online) if the Fx_Port is ready to accept fabric login request from the attached
Nx_Port. It should proceed and remain in the link-failure state (4) if and only if there is a
fault that prevents it from going to the online state (1).
1.3.6.1.3.42.2.1.2.3.1.5
The value of sysUpTime at the time the Fx_Port entered its current operational status. A
value of 0 indicates that the Fx_Port's operational status has not changed since the agent
last restarted.
Fabric OS 5.x MIB reference guide 103