swFCPortLipOuts
OID
Description
swFCPortLipLastAlpa
OID
Description
swFCPortWwn
OID
Description
swFCPortSpeed
OID
Description
Note
swFCPortName
Supported in Fabric OS 4.1.x and later.
OID
Description
swFCPortSpecifier
Syntax
Access
Status
Description
Note
164 SW MIB objects
1.3.6.1.4.1.1588.2.1.1.1.6.2.1.32
Counts the number of loop initializations that have been initiated by the port.
1.3.6.1.4.1.1588.2.1.1.1.6.2.1.33
Indicates the arbitrated-loop physical address (AL_PA) of the loop device that initiated the
last loop initialization.
1.3.6.1.4.1.1588.2.1.1.1.6.2.1.34
The WWN of the Fibre Channel port. The contents of an instance are in IEEE extended
format, as specified in FC-PH.
1.3.6.1.4.1.1588.2.1.1.1.6.2.1.35
The desired baud rate for the port.
The baud rate can be 1 Gbit/sec, 2 Gbit/sec, or 4 Gbit/sec. 4 Gbit/sec is applicable
only to the SAN Switch 4/32.
1.3.6.1.4.1.1588.2.1.1.1.6.2.1.36
A string that indicates the name of the addressed port.
The names should be persistent across switch reboots. Port names do not have to be
unique within a switch or within a fabric.
DisplayString
read-only
current
This string indicates the physical port number of the addressed port.
This string can be entered as argument on CLI commands such as portShow or wherever
a physical port number is expected.
The format of the string is: slot/port, where slot is present only for bladed systems.
Example for directors, such as 4/256 SAN Director:
swFCPortSpecifier.64 = 4/15
Example for non-bladed systems, such as SAN Switch 4/32:
swFCPortSpecifier.31 = 31