entPhysicalContainedIn

OID
Status
Description
Note

entPhysicalClass

OID
Status
Description
Note
118 Entity MIB objects
1.3.6.1.2.1.47.1.1.1.1.4
Current
The value of entPhysicalIndex for the physical entity that contains this physical entity. A
value of 0 indicates this physical entity is not contained in any other physical entity. Note
that the set of containment relationships defines a strict hierarchy; that is, recursion is not
allowed.
If a physical entity is contained by more than one physical entity (for example,
double-wide modules), this object should identify the containing entity with the lowest
value of entPhysicalIndex.
Value 0 for chassis entry. All containers have ContainedIn set to 1. All FRUs are contained
in their respective slot container entries.
1.3.6.1.2.1.47.1.1.1.1.5
Current
An indication of the general hardware type of the physical entity.
An agent should set this object to the standard enumeration value that most accurately
indicates the general class of the physical entity, or the primary class if there is more than
one.
If no appropriate standard registration identifier exists for this physical entity, then the
value
is returned. If the value is unknown by this agent, then the value
other(1)
is returned.
unknown(2)
The Core Switch 2/64, SAN Director 2/128, and 4/256 SAN Director can have the
following hierarchy of physical objects:
• Chassis: One entry (one row)
• Container: One entry for each FRU slot (eight port blades, two CPs, four power
supplies, three fans)
• Module: Eight entries for port blades, two entries for CPs, four entries for power
supplies, and three entries for fans
SAN Switch 2/32 can have the following hierarchy of physical objects:
• Chassis: One entry (one row)
• Container: One entry for each FRU slot (one switch blade, two power supplies, six
fans)
• Module: One entry for switch blade, up to two entries for power supplies, and up to
six entries for fans
SAN Switch 4/32 can have the following hierarchy of physical objects:
• Chassis: One entry (one row)
• Container: One entry for each FRU slot (one switch blade, two power supplies, three
fans)
• Module: 1 entry for switch blade, up to two entries for power supplies, and up to
three entries for fans